RM220-122 Mic/Headphone/GPIO module, 4 channels

[Warning]Warning

Do not connect any voltaged lines (for example Telephone, ISDN) to any output of the modules RM220-122, RM220-222 and RM220-223. External voltage will cause damages on internal circuits.

Analog reference voltage level0 dBu = 0.775 V (RMS)
Digital reference level0 dBFS = full scale modulation
Frequency range for measurements20 Hz ... 20 kHz
Sampling frequency44.1 kHz ... 48 kHz

A/D Converter

Max. input level18 dBu (electrically balanced)
Frequency response deviation< 0.5 dB
Gain0 ... 70 dB
Input sensitivity-66 dBu
Input impedance>= 8k ohm
Converter technology24 bit, (64 x oversampling Sigma-Delta)
Dynamic range typical 106 dB (A-weighted)
THD+N< -80 dB (-1 dBFS, 0 dB analog gain) / < 0.01%
Common mode rejection> 60 dB
Crosstalk< -90 dB

D/A Converter

Max. output level (headphones, single ended)15 dBu (unbalanced)
Frequency response deviation< 0.3 dB
Output impedancetypical 17 ohm
Load impedance >= 80 ohm (outputs short circuit protected)
Converter technology24 bit, (128 x oversampling Sigma-Delta)
Dynamic rangetypical 108 dB (A-weighted)
THD+N< -82 dB (-1 dBFS) / < 0.008%
Crosstalk< -90 dB

General Purpose Inputs / Outputs (GPI/GPO)

2 non-insulated analog control inputs (ACI) to connect external potentiometers for level control. (Connect 10k ohms linear potentiometer between wiper and GND (left detend), leave open right detend of potentiometer.)Potentiometer 10k ohm to GND or 0 ... 3.3V control voltage, overvoltage protected
2 GPIs: non-insulated TTL-Inputs with internal pull up resistor (10k ohms to 5 V)switch contact to GND or TTL level (low active), overvoltage protected
4 GPOs: electronic relay, insulatedmax. 0.2 A / 30 V DC / 25 V AC