![]() | Warning |
---|---|
Do not connect any voltaged lines (for example Telephone, ISDN) to any output of the modules RM420-122, RM420-222 and RM420-223. External voltage will cause damages on internal circuits. |
All GPOs use fully galvanic isolated PhotoMOS relays, suitable for AC or DC voltage.
Maximum peak switched voltage: 30V AC or DC (resettable fuse).
Maximum rated current: 0,2A (resettable fuse).
Relay type: Matsushita AQV212S. For more information please visit :www.matsushita.co.uk
All GPIs are fully galvanic isolated using an optocoupler (TLP281) with current limiter (LM317L with 300 ohms).
ON voltage: greater + 4 V, up to +30 V.
OFF voltage: 0 V ... + 1,5 V.
ON current: 4 mA.
TTL-Inputs with internal pull up resistor (10k ohms to 5 V).
These TTL-inputs are not galvanic isolated!
Please connect switch between GPI and GPI GND!
Analog control input to connect external potentiometers for level control.
These analog inputs are not galvanic isolated!
Please connect 10kOhm linear potentiometer between ACI (wipe contact) and ACI GND (left detent). Leave open right detent of potentiometer!
All AES3/EBU inputs and outputs as well as all Ethernet connectors are galvanic isolated with pulse transformers.
All other signals are not galvanic isolated from ground potential!